Dark rod soft-sealed gate valve 2024
Z45X-16Q can be widely used in fluid pipelines for tap water, sewage, construction, petroleum, chemical, food, pharmaceuticals, light textiles, electricity, ships, metallurgy, and energy systems as a regulating and shut-off device.
Dark rod soft-sealed gate valve 2024
Dark rod soft-sealed gate valve is a type of valve that is commonly used in industrial applications. It is designed to control the flow of liquids and gases in a pipeline by opening and closing a gate. The dark rod soft-sealed gate valve is named for its dark rod, which is used to operate the valve, and its soft-sealed design, which provides a tight seal to prevent leakage.
The dark rod soft-sealed gate valve is a popular choice for applications where a tight seal is required, such as in the oil and gas industry. Its soft-sealed design ensures that the valve can be operated smoothly and without any leaks. The dark rod, which is attached to the gate, allows for easy operation of the valve, even in hard-to-reach locations.
One of the key advantages of the dark rod soft-sealed gate valve is its ability to handle high temperatures and pressures. This makes it an ideal choice for applications where the valve will be exposed to extreme conditions. The soft-sealed design of the valve ensures that it can maintain a tight seal even under high temperatures and pressures, making it a reliable and efficient option for industrial applications.
In addition to its high temperature and pressure capabilities, the dark rod soft-sealed gate valve is also known for its durability. The valve is constructed from high-quality materials that are designed to withstand the rigors of industrial use. This ensures that the valve will continue to perform reliably over time, even in demanding conditions.
Another advantage of the dark rod soft-sealed gate valve is its versatility. The valve can be used in a wide range of applications, from controlling the flow of water in a municipal water system to regulating the flow of chemicals in a manufacturing plant. Its ability to handle a variety of liquids and gases makes it a versatile option for many different industries.
Overall, the dark rod soft-sealed gate valve is a reliable and efficient option for controlling the flow of liquids and gases in industrial applications. Its high temperature and pressure capabilities, durability, and versatility make it a popular choice for a wide range of industries. Whether you need to control the flow of water, oil, gas, or chemicals, the dark rod soft-sealed gate valve is a dependable option that will meet your needs.
Plant






Application areas

oil and gas

Chemical industry

Food and beverage

Steam industry

Shipbuilding and Mining

Other industries
Honor

FAQ

1. Before installation, check whether the specifications, pressure, temperature, and corrosion resistance of the butterfly valve meet the usage requirements. Inspect all parts for damage or looseness.
2. This butterfly valve can be installed on pipes at any angle, preferably in a closed position; when welding the pipe flange, cover the valve sealing surface with a plate to prevent particles and debris from damaging the sealing surface. After welding, remove the valve, clean the sealing surface and the inner cavity of the pipe, and then install and secure the valve.
3. During installation, pay attention to the pressure direction when the valve is in the closed state.
4. Before installation, thoroughly clean the sealing surfaces (both ends, butterfly plate sealing surface, and valve seat sealing surface) to remove dust and dirt.
5. Before installation, perform a trial operation of the butterfly valve; it should open and close smoothly, and the open/close position should match the pointer position. Manual operation: clockwise to close, counterclockwise to open; do not apply additional force once the pointer is in position.
7. When conducting pressure tests on the valve, do not use a single flange for installation and pressure testing; double flanges must be used. When tightening bolts, do so in a symmetrical and alternating manner; do not tighten them sequentially. 9. The limit bolts have been adjusted before leaving the factory and should not be easily adjusted. If the drive device is electric or pneumatic, please read the accompanying drive device manual.
10. If the valve opens and closes abnormally, investigate the cause for repair and elimination; do not use force to operate the valve, as this may cause damage. 11. If the valve malfunction cannot be resolved, please notify our company for product installation, usage, and after-sales service.

If there are no other special requirements for the valve, it can be ordered according to the valve's number. This requires the user to understand the valve number description when ordering the product. Although this may be difficult for the user, selecting the appropriate number based on the parameters of the product they need can ensure that the provided valve fully meets the user's requirements.

1. When storing, the valve passage at both ends must be blocked with cover plates. It should be stored indoors in a dry and ventilated environment, and should be regularly checked and cleaned of dirt. Anti-rust oil should be applied to exposed machined surfaces to prevent rust.
2. Valves must be stored in a dry room and should not be placed outside to avoid damage.
3. Before transportation, valves must be tested and debugged according to the requirements of the contract or standard requirements to prevent user misoperation. For pneumatic or electric ball valves, the power source requirements for the corresponding devices must be listed according to the instructions of the pneumatic or electric device. If the user needs testing and inspection, it must be conducted according to standard requirements to prevent the product from failing to meet its performance due to incorrect testing methods. After pressure testing, any accumulated water inside the valve must be cleaned out before storage.
4. When installing the valve, the cover plates at both ends of the valve must be removed. For valves connected by welding, protective measures must be taken during the welding installation process to prevent adverse effects on the valve due to high temperatures. 5. For valves with a specific installation direction, directional arrows must be marked on the valve body to prevent incorrect installation.

1. Manual valve: When the handle is in a parallel position to the pipeline, the valve is in the open position; when it is at 90 degrees, the valve is in the closed position. Turning the handle clockwise closes the valve, while turning it counterclockwise opens the valve.
2. Worm gear driven valve: Identify using the indicator device installed on the upper part of the valve; turning the handle clockwise closes the valve, while turning it counterclockwise opens the valve. 3. Valves operated by pneumatic, electric, gas-liquid linkage, or hydraulic linkage: Operate according to the relevant actuator manual.