Full Bore Welded Ball Valve
The QA61F-25C full-bore welded ball valve is a type of ball valve that has a full-bore passage, meaning the internal passage diameter of the valve is the same as the diameter of the pipeline, which does not create fluid resistance or pressure drop.
Full Bore Welded Ball Valve
The full-bore welded ball valve is a high-performance valve, and here is a detailed introduction to it:
Structural Features
The valve body of the full-bore welded ball valve adopts an integral welded structure, with no external leakage points, ensuring high sealing performance. Its ball passage is designed for full bore, resulting in low flow resistance and high flow capacity, capable of meeting the demands of rapid flow. In addition, key components such as the valve stem and seat are made from high-quality materials and advanced processes, ensuring the stability and reliability of the valve during long-term operation.
Performance Advantages
1. Sealing Performance: The sealing ring of the full-bore welded ball valve is made from high-quality materials, with strong adaptability to changes in pressure and temperature, ensuring no leakage within the specified range.
2. Corrosion Resistance: The main materials are resistant to high temperatures and corrosion, making them durable.
3. Easy Operation: It features quick opening and closing, with flexible operation, suitable for remote control and automatic control.
Application Fields
Full-bore welded ball valves are widely used in various industries such as petroleum, natural gas, chemical, electric power, and construction, for controlling and regulating fluid media, ensuring the safety and operation of pipeline systems.
In summary, the full-bore welded ball valve, with its performance and wide range of applications, has become an indispensable component in industrial pipeline systems.
Plant






Application areas

oil and gas

Chemical industry

Food and beverage

Steam industry

Shipbuilding and Mining

Other industries
Honor

FAQ

1. Before installation, check whether the specifications, pressure, temperature, and corrosion resistance of the butterfly valve meet the usage requirements. Inspect all parts for damage or looseness.
2. This butterfly valve can be installed on pipes at any angle, preferably in a closed position; when welding the pipe flange, cover the valve sealing surface with a plate to prevent particles and debris from damaging the sealing surface. After welding, remove the valve, clean the sealing surface and the inner cavity of the pipe, and then install and secure the valve.
3. During installation, pay attention to the pressure direction when the valve is in the closed state.
4. Before installation, thoroughly clean the sealing surfaces (both ends, butterfly plate sealing surface, and valve seat sealing surface) to remove dust and dirt.
5. Before installation, perform a trial operation of the butterfly valve; it should open and close smoothly, and the open/close position should match the pointer position. Manual operation: clockwise to close, counterclockwise to open; do not apply additional force once the pointer is in position.
7. When conducting pressure tests on the valve, do not use a single flange for installation and pressure testing; double flanges must be used. When tightening bolts, do so in a symmetrical and alternating manner; do not tighten them sequentially. 9. The limit bolts have been adjusted before leaving the factory and should not be easily adjusted. If the drive device is electric or pneumatic, please read the accompanying drive device manual.
10. If the valve opens and closes abnormally, investigate the cause for repair and elimination; do not use force to operate the valve, as this may cause damage. 11. If the valve malfunction cannot be resolved, please notify our company for product installation, usage, and after-sales service.

If there are no other special requirements for the valve, it can be ordered according to the valve's number. This requires the user to understand the valve number description when ordering the product. Although this may be difficult for the user, selecting the appropriate number based on the parameters of the product they need can ensure that the provided valve fully meets the user's requirements.

1. When storing, the valve passage at both ends must be blocked with cover plates. It should be stored indoors in a dry and ventilated environment, and should be regularly checked and cleaned of dirt. Anti-rust oil should be applied to exposed machined surfaces to prevent rust.
2. Valves must be stored in a dry room and should not be placed outside to avoid damage.
3. Before transportation, valves must be tested and debugged according to the requirements of the contract or standard requirements to prevent user misoperation. For pneumatic or electric ball valves, the power source requirements for the corresponding devices must be listed according to the instructions of the pneumatic or electric device. If the user needs testing and inspection, it must be conducted according to standard requirements to prevent the product from failing to meet its performance due to incorrect testing methods. After pressure testing, any accumulated water inside the valve must be cleaned out before storage.
4. When installing the valve, the cover plates at both ends of the valve must be removed. For valves connected by welding, protective measures must be taken during the welding installation process to prevent adverse effects on the valve due to high temperatures. 5. For valves with a specific installation direction, directional arrows must be marked on the valve body to prevent incorrect installation.

1. Manual valve: When the handle is in a parallel position to the pipeline, the valve is in the open position; when it is at 90 degrees, the valve is in the closed position. Turning the handle clockwise closes the valve, while turning it counterclockwise opens the valve.
2. Worm gear driven valve: Identify using the indicator device installed on the upper part of the valve; turning the handle clockwise closes the valve, while turning it counterclockwise opens the valve. 3. Valves operated by pneumatic, electric, gas-liquid linkage, or hydraulic linkage: Operate according to the relevant actuator manual.