Stone cave valve

Mobile: +8618624918289

E-mail: 290004946@qq.com

Address: Xingyang Gaoshan Town Valve Industrial Park

+
  • 法兰球阀(钢制焊接).jpg

Flanged Ball Valve (Steel Welded)


Flanged ball valves occupy an important position in the valve market due to their superior performance and wide range of applications.

Classification:

Service Support:

Flanged Ball Valve (Steel Welded)

Plant

Factory workshop
Factory workshop
Factory workshop
Factory workshop
Factory workshop
Factory workshop

Application areas

oil and gas

oil and gas


Chemical industry

Chemical industry


Food and beverage

Food and beverage


Steam industry

Steam industry


Shipbuilding and Mining

Shipbuilding and Mining


Other industries

Other industries


Honor

Stone cave valve

FAQ


FAQ

1. Before installation, check whether the specifications, pressure, temperature, and corrosion resistance of the butterfly valve meet the usage requirements. Inspect all parts for damage or looseness.
2. This butterfly valve can be installed on pipes at any angle, preferably in a closed position; when welding the pipe flange, cover the valve sealing surface with a plate to prevent particles and debris from damaging the sealing surface. After welding, remove the valve, clean the sealing surface and the inner cavity of the pipe, and then install and secure the valve.
3. During installation, pay attention to the pressure direction when the valve is in the closed state.

4. Before installation, thoroughly clean the sealing surfaces (both ends, butterfly plate sealing surface, and valve seat sealing surface) to remove dust and dirt.
5. Before installation, perform a trial operation of the butterfly valve; it should open and close smoothly, and the open/close position should match the pointer position. Manual operation: clockwise to close, counterclockwise to open; do not apply additional force once the pointer is in position.
7. When conducting pressure tests on the valve, do not use a single flange for installation and pressure testing; double flanges must be used. When tightening bolts, do so in a symmetrical and alternating manner; do not tighten them sequentially. 9. The limit bolts have been adjusted before leaving the factory and should not be easily adjusted. If the drive device is electric or pneumatic, please read the accompanying drive device manual.
10. If the valve opens and closes abnormally, investigate the cause for repair and elimination; do not use force to operate the valve, as this may cause damage. 11. If the valve malfunction cannot be resolved, please notify our company for product installation, usage, and after-sales service.


FAQ

If there are no other special requirements for the valve, it can be ordered according to the valve's number. This requires the user to understand the valve number description when ordering the product. Although this may be difficult for the user, selecting the appropriate number based on the parameters of the product they need can ensure that the provided valve fully meets the user's requirements.


FAQ

1. When storing, the valve passage at both ends must be blocked with cover plates. It should be stored indoors in a dry and ventilated environment, and should be regularly checked and cleaned of dirt. Anti-rust oil should be applied to exposed machined surfaces to prevent rust.
2. Valves must be stored in a dry room and should not be placed outside to avoid damage.
3. Before transportation, valves must be tested and debugged according to the requirements of the contract or standard requirements to prevent user misoperation. For pneumatic or electric ball valves, the power source requirements for the corresponding devices must be listed according to the instructions of the pneumatic or electric device. If the user needs testing and inspection, it must be conducted according to standard requirements to prevent the product from failing to meet its performance due to incorrect testing methods. After pressure testing, any accumulated water inside the valve must be cleaned out before storage.
4. When installing the valve, the cover plates at both ends of the valve must be removed. For valves connected by welding, protective measures must be taken during the welding installation process to prevent adverse effects on the valve due to high temperatures. 5. For valves with a specific installation direction, directional arrows must be marked on the valve body to prevent incorrect installation.


FAQ

1. Manual valve: When the handle is in a parallel position to the pipeline, the valve is in the open position; when it is at 90 degrees, the valve is in the closed position. Turning the handle clockwise closes the valve, while turning it counterclockwise opens the valve.
2. Worm gear driven valve: Identify using the indicator device installed on the upper part of the valve; turning the handle clockwise closes the valve, while turning it counterclockwise opens the valve. 3. Valves operated by pneumatic, electric, gas-liquid linkage, or hydraulic linkage: Operate according to the relevant actuator manual.

Key words:

Flanged Ball Valve (Steel Welded)

Free Quote

Note: If you have any suggestions, please leave a message or send an email to us, and we will reply to you within 1 working day after receiving the message email.

Related Products

The Q61F-25C fully welded ball valve is a valve that uses hydraulic or pneumatic control to rotate the ball for opening, closing, and regulating flow.
The Q361F-25C fully welded turbine ball valve is a high-performance valve widely used in various fields such as petroleum, natural gas, chemical industry, power generation, metallurgy, and shipbuilding.
The QA61F-25C full-bore welded ball valve is a type of ball valve that has a full-bore passage, meaning the internal passage diameter of the valve is the same as the diameter of the pipeline, which does not create fluid resistance or pressure drop.
The steel vertical check valve is known for its superior performance characteristics and wide range of applications.

Free Quote